HKD YuKen variable pump machine
Features and benefits : Products performance and advantages ·Template structure of the high-rigidity design, both T-slots and conventional screw holes make mold is easy to install;·Equipped with imported low-noise and high-efficiency variable pump system, saving energy 30%-60% and oil and water 20%-40%;·High-precision filter makes the hydraulic oil clean and maintains it within NAS8;·The use of Taiwan TECHMATION/MIRLE color screen control system
ITEM / SPECIFICATION | HKD-138T |
A | B | C |
INJECTIONUNIT | Screw diameter | mm | 38 | 40 | 42 |
Screw L/D ratio | L/D | 22 | 20 | 18.5 |
Shot size(theoretical) | CM | 244 | 270 | 298 |
Injection weight | G | 220 | 240 | 165 |
Injection rate | G/S | 108 | 125 | 130 |
Injection pressure | MPA | 176 | 158 | 143 |
Screw speed | RMP | 200 |
CLAMPING UNIT | Clamping force | KN | 1380 |
Toggle stroke | MM | 370 |
Space between tie-bars | MM | 425*405 |
Max.mould height | MM | 460 |
Min.mould height | MM | 170 |
Ejector stroke | MM | 120 |
Ejector Tonnage | KN | 33 |
OTHERS | Max pump pressure | MPA | 14 |
Pump motor power | KW | 11 |
Heating power | KW | 7.7 |
Machine dimensions (L*W*H) | M | 4.9*1.25*1.85 |
Machine weight | T | 4 |
Mould Location Recess Diameters | ¢ | 125
|